Ver T Fix - Independent test results:

Wind Load Positive Pressure - FP* = 3.23kPa
(equates to wind speed of 162mph)
Wind Load Negative Pressure - FP* = 0.65kPa
(equates to wind speed of 72mph)

The above results show Ver T Fix performance levels comfortably exceeding any internal air pressures that are likely to be encountered in buildings.

FP* = Failure Pressure

For more detailed results click here.

RC3 Panels with Gravity Frames

More images

Enquiry checklist

  • Product ref: RC3
  • GA Gravity Frame code
  • GA sheet code or special pattern details
  • Panel sizes, o/a length and width or structural opening details
  • Number of panels
  • Surface finish: Anodised, satin brushed, powder coated, mill

Your Basket

0 item(s)
Total: £0.00
incl. VAT

View Basket

GA Processing

Radiator/Vent Covers Fixing Instructions

Please use the links below for fixing instructions on any of our Radiator/Vent Covers products.

Posi-Grip Instant Access - Independent test results:

Wind Load Positive Pressure - FP* = 15.00kPa
(equates to wind speed of 350mph)
Wind Load Negative Pressure - FP* = 1.48kPa
(equates to wind speed of 107mph)

The above results show Posi-Grip Instant Access performance levels comfortably exceeding any internal air pressures that are likely to be encountered in buildings.

FP* = Failure Pressure